Approach

How the work is organized

Five phases. Each can be bought on its own and builds on the one before, and the measured baseline from the early phases carries through to the end. Stride delivers the first three phases. The last two are delivered with commissioning, controls and implementation partners.

01 · Clarity

Performance Snapshot

Available

A remote baseline built from utility bills, with no site visit. For portfolios, it ranks which buildings to look at first.

Inputs 12–36 months of utility bills, floor area, building type and location.

What you get

  • Weather-normalized energy baseline using change-point regression
  • Benchmarks against ASHRAE Standard 100 and CBECS, with ENERGY STAR score where applicable
  • Estimated split of energy use into heating, cooling and base load
  • Building Performance Standard exposure screen
  • Portfolios: site prioritization and readiness surveys
  • A clear recommendation on whether a Digital Mirror is warranted

02 · Clarity

Digital Mirror

Proof of concept

Wireless current and environmental sensors, and a calibrated, physics-based energy model, compared in live analytics. The kit installs in one day and does not connect to the building network.

Inputs Utility data, one install day for wireless sensors (current sensors installed by a licensed electrician), and a building scan where drawings are missing or unreliable.

What you get

  • Circuit-level current with derived energy use, equipment runtime, occupancy, and CO₂, temperature and humidity by zone
  • As-built floor plan and model geometry, from a scan where warranted
  • Calibrated EnergyPlus model, checked against ASHRAE Guideline 14 criteria
  • Live dashboards comparing measured and modeled performance
  • Operational findings and prioritized efficiency opportunities
  • Measure bundles run in the model, with cash flow, payback and emissions results
  • Decarbonization roadmap and implementation plan
  • Audit-style, retro-commissioning and compliance reports from the same data when needed

03 · Clarity

Digital Twin

Roadmap

An operational digital twin is a live, calibrated model of how the building runs, connected to the systems that run it. When the Digital Mirror’s results justify it, its data is connected to the building automation and maintenance systems, with fault detection on the same data, under the owner’s IT/OT governance. In the U.S. Department of Energy’s Smart Energy Analytics Campaign, run by Lawrence Berkeley National Laboratory, participants using fault detection software reported median energy savings of 9%, with about a two-year simple payback.

Source: LBNL, Proving the Business Case for Building Analytics (2020)

What you get

  • BAS integration with the controls and IT teams, read-only first
  • An independent, owner-owned data layer that every application shares
  • Permanent monitoring, with fault detection and diagnostics (FDD) from any vendor on the same data
  • IT/OT governance plan for connected building systems
From Digital Mirror to operational digital twin At the center of the Digital Twin is an independent, owner-owned data layer with open, tagged data, inside a Sense, Analyze, Decide, Act, Verify loop. A fault detection and diagnostics platform connects from above, the building automation system from the left, maintenance management software (CMMS) from the right, and the Digital Mirror's sensors and calibrated model from below. Everything sits inside the owner's IT/OT governance. IT/OT governance · open standards · owner-owned data OPERATIONAL Digital Twin Independent data layer owner-owned, open data Sense Analyze Decide Act Verify FDD platform any vendor, on the same data BAS / controls Read-only first, control when it pays CMMS / work orders Findings become maintenance tasks Digital Mirror wireless sensors + calibrated model
The owner holds the data layer at the center. The Digital Mirror is the first data source, and fault detection, controls and maintenance software connect to the same data.

04 · Action

Project Delivery

Roadmap

The implementation plan from the Digital Mirror is carried into delivery: efficiency, electrification, solar, battery storage and microgrid projects, plus operational fixes carried through to completion. Delivered with partners.

What you get

  • Final project scope, procurement support and contractor coordination from the Digital Mirror business case
  • Fault-to-fix coordination with controls and service contractors
  • Implementation support and owner’s representation

05 · Action

Continuous Improvement

Roadmap

Building performance drifts over time. Overrides accumulate, sensors fail, and a tuned sequence can stop working without anyone noticing. Continuous Improvement keeps monitoring in place and follows each finding through to a completed repair, checked against the calibrated model. Delivered with partners.

What you get

  • Monitoring-based and ongoing commissioning
  • Managed FDD review
  • Savings verification and BPS reporting

Not sure where to start?

Most buildings start with a Performance Snapshot. It needs utility bills and no site visit.

Get in touch